Delta Electronics — 11.4.3.1 OD 1XXXh communication object group

ASDA-B3 CANopen Mode Object 1400h - 1403h: RPDO communication parameter 11 Object function: Bit Bit The COB-ID setting format is as follows: 11-43 Index 1400h - 1403h Name Receive PDO parameter Object code RECORD Data type PDO CommPar Access RW Sub-index 0 Description Maximum number of sub-index supported Data type UNSIGNED8 Access RO PDO mapping No Setting range 5 Default 5 Sub-index 1 Description COB-ID used by PDO Data type UNSIGNED32 Access RW PDO mapping No Setting range UNSIGNED32 Default Node-ID: 0 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 10 - Bit 0 COB-ID The data size is 10-bit.

Bit 30 - Bit 11 - - Bit 31 PDO function switch 0: enable PDO function. 1: disable PDO function. Enable / disable the PDO function to determine if PDO is used in the Operational state. Communication object Object parameter COB-ID DEC (HEX) R PDO1 _ 1400h 512 (200h) + Node-ID R PDO2 _ 1401h 768 (300h) + Node-ID R PDO3 _ 1402h 1024 (400h) + Node-ID R PDO4 _ 1403h 1280 (500h) + Node-ID