ASDA-B3 CANopen Mode Bit 11 Bits 4 - 6 are individually defined according to the mode, as shown in the following table: Finite state automation (as shown in the following diagram) defines the behavior of a servo drive system. Each state represents an internal or external behavior. For example, point-to-point motion can only be received and executed in the operation enabled state.
Start 0, 1 Switch On disabled 15 2 7 10 Ready to switch on Fault 12 3 6 9 Switch on 8 13, 14 4 16 5 Enbled Quick Stop 11 Operation 11-51 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 0 Switch on - Bit 1 Enable voltage - Bit 2 Quick stop (B-connect) - Bit 3 Enable operation - Bit 4 - Bit 6 Operation mode definition This bit is individually defined according to the control mode, as shown in the following table.
Bit 7 Fault reset - Bit 8 Halt - Bit 9 - Bit 15 - - Bit Operation mode definition Profile Position Mode Homing Mode Profile Velocity Mode Profile Torque Mode Interpolated Position Mode Bit 4 Command triggered (rising-edge triggered) Homing (rising-edge triggered) - Bit 5 Command to take immediate effect - - Bit 6 0: absolute position command 1: relative position command - -