Delta Electronics — 11.4.3.3 OD 6XXXh communication object group

ASDA-B3 CANopen Mode Object 6061h: Modes of operation display 11 Object function: This object displays the current operation mode. Object 6062h: Position demand value (PUU) Object function: This command position is the interpolation command calculated by the servo internal interpolator. This command passes through the servo internal filter. For detailed position, refer to the servo architecture diagram of each mode. Object 6063h:

Position actual internal value 11-55 Index 6061h Name Modes of operation display Object code VAR Data type INTEGER8 Access RO PDO mapping Yes Setting range INTEGER8 Default 0 Index 6062h Name Position demand value Object code VAR Data type INTEGER32 Access RO PDO mapping Yes Setting range INTEGER32 Default 0 Unit PUU Index 6063h Name Position actual internal value Object code VAR Data type INTEGER32 Access RO PDO mapping Yes Setting range INTEGER32 Default 0 Unit Pulse (unit for encoder pulse resolution) ASDA-A2 corresponds to 1,280,000 pulses per motor rotation. ASDA-A3 / ASDA-B3 correspond to 16,777,216 pulses per motor rotation.