Delta Electronics — Motion control type

Troubleshooting ASDA-B3 General type (continued) 12 Note: if the servo drive shows an alarm that is not in this table, contact the local distributor or technician.

Motion control type 12-4 Error type Servo state Display Alarm name ALM WARN ON OFF AL068 Absolute data transmitted by I/O is in error ○ ○ AL069 Wrong motor type ○ ○ AL06A Absolute position is lost ○ ○ AL070 Encoder did not complete the set-up command issued by servo drive ○ ○ AL072 Encoder overspeed ○ ○ AL073 Encoder memory error ○ ○ AL074 Encoder single-turn absolute position error ○ ○ AL075 Encoder absolute number of turns is in error ○ ○ AL077 Encoder internal error ○ ○ AL079 Encoder parameter error ○ ○ AL07B Encoder memory busy ○ ○ AL07C Command to clear the absolute position is issued when the motor speed is over 200 rpm ○ ○ AL07D Motor stops operating when servo drive power is cycled before AL07C is cleared ○ ○ AL07E Encoder clearing procedure error ○ ○ AL07F Encoder version error ○ ○ AL083 Servo drive outputs excessive current ○ ○ AL085 Regeneration error ○ ○ AL086 Input voltage is too high ○ ○ AL088 Servo function operational warning ○ ○ AL089 Current detection interference ○ ○ AL08A Auto-tuning function - command error ○ ○ AL08B Auto-tuning function - pause time is too short ○ ○ AL08C Auto-tuning function - inertia estimation error ○ ○ AL099 DSP error ○ ○ AL521 Vibration elimination parameter error ○ ○ AL35F Emergency stop during deceleration ○ ○ AL3CF Emergency stop ○ ○ Error type Servo state Display Alarm name ALM WARN ON OFF AL207 Parameter group of PR#8 is out of range ○ ○ AL209 Parameter number of PR#8 is out of range ○ ○ AL213 Parameter setting of PR#8 is in error ○ ○ AL215 Write parameters:

read-only ○ ○ AL217 Write parameters: parameter locked ○ ○ AL231 Monitoring item of PR#8 is out of range ○ ○ AL235 Position counter overflow warning ○ ○ AL237 Indexing coordinate is undefined ○ ○ AL245 PR positioning timeout ○ ○