Delta Electronics — 12.2 Causes and corrective actions

Troubleshooting ASDA-B3 12 12-10 AL006 Overload Checking method and corrective action 3. Check if the wiring of UVW and the encoder cables is correct. 4. Send your servo drive back to the distributor or contact Delta. How to clear the alarm? DI.ARST AL007 Excessive deviation of Speed command Trigger condition and cause Condition: deviation between the Speed command and the feedback speed exceeds the allowable range set by P2.034. Cause: 1. A drastic change in the input Speed command. 2. Improper setting of P2.034 (Speed command error warning). 3. Incorrect wiring of UVW and the encoder cables. Checking method and corrective action 1.

Use the signal detector to check if the input analog voltage signal is normal. If not, adjust the rate of change for input signals or enable the filter function. 2. Check if the value of P2.034 (Speed command error warning) is set properly. 3. Check if the wiring of UVW and the encoder cables is correct. How to clear the alarm? DI.ARST AL008 Abnormal pulse command Trigger condition and cause Condition: the input frequency for the pulse command is over the allowable value for the hardware interface. Cause: the pulse command frequency is higher than the rated input frequency. Checking method and corrective action Use the scope to check if the input frequency is higher than the rated frequency.

Correctly set the input pulse frequency. How to clear the alarm? DI.ARST AL009 Excessive deviation of Position command Trigger condition and cause Condition: deviation between the Position command and the feedback position exceeds the allowable range set by P2.035. Cause: 1. The maximum position deviation is set too low. 2. Gain value is set too low. 3. Torque limit is set too low. 4. Excessive external load.