ASDA-B3 Troubleshooting 12 12-13 AL013 Emergency stop Trigger condition and cause The emergency stop button is pressed. Checking method and corrective action Check and make sure the emergency stop button is off. How to clear the alarm? Set DI.EMGS to off to clear the alarm. AL014 Reverse limit error Trigger condition and cause Condition: reverse limit switch is triggered. Cause: 1. Reverse limit switch is triggered. 2. Servo system is unstable. Checking method and corrective action 1. Check and make sure the reverse limit switch is off. 2. Check the parameter setting or re-estimate the motor capacity. How to clear the alarm?
The alarm is automatically cleared after the motor moves away from the limit. AL015 Forward limit error Trigger condition and cause Condition: forward limit switch is triggered. Cause: 1. Forward limit switch is triggered. 2. Servo system is unstable. Checking method and corrective action 1. Check and make sure the forward limit switch is off. 2. Check the parameter setting or re-estimate the motor capacity. How to clear the alarm? The alarm is automatically cleared after the motor moves away from the limit. AL016 Abnormal IGBT temperature Trigger condition and cause Condition: temperature of IGBT is abnormal. Cause: 1.
The load is over the rated range and the servo drive is in a continuous overload condition. 2. The servo drive output is short-circuited. Checking method and corrective action 1. Check if the motor is overloaded or over-current. If so, try increasing the motor's capacity or reducing the load. 2. Check if the wiring of servo drive output is correct. How to clear the alarm? DI.ARST