Delta Electronics — 12.2 Causes and corrective actions

Troubleshooting ASDA-B3 12 12-18 AL027 Encoder internal reset error Trigger condition and cause Condition: encoder reset error. Cause: encoder reset. Checking method and corrective action 1. Check if the encoder signal cable is firmly connected. 2. Check if the power supply for the encoder is stable and make sure to use shielded cable. 3. Check if the operating temperature is over 95°C (203°F). Identify the cause for the high temperature and do not restart the operation before the temperature drops to the allowable range. If the issue persists, send your servo motor back to the distributor or contact Delta. How to clear the alarm? Cycle power on the servo drive.

AL028 Encoder voltage error or encoder internal error Trigger condition and cause Condition: servo drive charging circuit is not removed so the battery voltage is higher than the specified value (> 3.8V) or the encoder signal is in error. Cause: 1. Voltage level of the battery is too high. 2. Encoder internal error. Checking method and corrective action 1. Follow the testing procedure for overvoltage and overcurrent and troubleshoot the following. This automatically clears AL028. (a) Check the servo drive charging circuit. Avoid incorrect wiring. If Pin 1 (5V) of CN2 is connected to BAT+, it means the power (5V) of the servo drive is being charged to the battery.

(b) Check if the battery is correctly installed. (Voltage > 3.8V) 2. Check if the motor is properly grounded. Make sure the power cable (green end) is grounded to the servo drive heat sink. 3. Check if the connection for the encoder signal cable is normal. Make sure the encoder signal cable is separated from the power supply or any high-current cables to avoid interference. 4. Use shielded cable for the encoder. If the issue persists, send your servo drive and motor back to the distributor or contact Delta. How to clear the alarm? Cycle power on the servo drive.