ASDA-B3 Troubleshooting 12 12-19 AL029 Gray code error Trigger condition and cause Absolute position error. Checking method and corrective action Cycle power on the servo drive to operate the motor. Then, check if the alarm occurs again. If the issue persists, replace the encoder. How to clear the alarm? Cycle power on the servo drive. AL030 Motor crash error Trigger condition and cause Condition: when the motor hits the device, the torque reaches the value set by P1.057 and lasts for the time set by P1.058. Cause: 1. Check if the function of motor hard stop (P1.057) is enabled. If so, set P1.057 to 0. 2. Check if the value set by P1.057 is too low and the time set by P1.058 is too short.
Set P1.057 according to the actual torque. If P1.057 is set too low, it may lead to malfunction; if P1.057 is set too high, it may lose the protection function. Checking method and corrective action Cycle power on the servo drive to operate the motor. Then, check if the alarm occurs again. If the issue persists, replace the encoder. How to clear the alarm? DI.ARST AL031 Motor power cable wiring error / disconnection Trigger condition and cause Condition: incorrect wiring or disconnection of the motor power cable (U, V, W) and ground wire (GND). Cause: incorrect wiring or disconnection of the power cable (U, V, W) and ground wire (GND).
The switch for cut-off detection is set by P2.065 [Bit 9], which default is set to disable. The switch for wiring error detection is set by P2.065 [Bit 8], which default is set to disable. Checking method and corrective action Check if the motor power cable (U, V, W) and ground wire (GND) are firmly connected. Follow the instructions in this user manual for correct wiring and proper grounding. How to clear the alarm? Cycle power on the servo drive.