ASDA-B3 Troubleshooting 12 12-21 AL044 Servo function overload warning Trigger condition and cause Condition: when the motor controlling function of the servo drive is overloaded, the motion control function is affected, causing error in the PR operation. Cause: servo function overload warning. Checking method and corrective action 1. If using a filter, see if using this filter is necessary. 2. Set P2.066 [Bit 4] to 1 to disable this alarm. How to clear the alarm? 1.
Disable the filter if it is not required, such as the low-pass filter (P1.006 - P1.008), moving filter (P1.068), low-frequency vibration suppression (P1.025 - P1.028), vibration elimination (P1.089 - P1.094), Notch filter (1st to 5th sets), percentage of friction compensation (P1.062), and motor hard stop (torque percentage) (P1.057). 2. Set P2.066 [Bit 4] to 1 and cycle power on the servo drive. AL045 E-Gear ratio value error Trigger condition and cause Condition: when the value of the E-Gear ratio exceeds the range (1/4 - 262144), this alarm occurs once power is cycled to the servo drive. Cause: E-Gear ratio value is found to be in error after the servo drive is powered on.
Checking method and corrective action Check if the value of the E-Gear ratio is within the allowable range (1/4 - 262144). If not, correct the value and then cycle power on the servo drive. How to clear the alarm? Cycle power on the servo drive after the value is corrected. AL053 Motor parameters are not confirmed Trigger condition and cause Condition: if the Motor Parameter Identification Wizard function has not been executed or the identification failed, once the servo is on, this alarm is triggered. Cause: the motor has not executed the Motor Parameter Identification Wizard function or fails to execute it.
Checking method and corrective action Execute or re-execute the Motor Parameter Identification Wizard function. How to clear the alarm? Switch the servo to the Servo Off state to clear this alarm.