Delta Electronics — 12.2 Causes and corrective actions

ASDA-B3 Troubleshooting 12 12-23 AL060 Absolute position is lost Trigger condition and cause Condition: losing the recorded number of revolutions because of low battery voltage or loss of power. Cause: 1. Voltage level of the battery is too low. 2. The battery is replaced when the main power of the servo drive is off. 3. The battery is not installed when the absolute function is enabled. 4. Poor connection or disconnection of the battery power circuit. Checking method and corrective action 1. Check if the battery voltage is below 2.8V. Re-establish the absolute origin coordinates after replacing the battery. 2. Do not replace or remove the battery when the servo drive’s main power is off. 3.

Follow these instructions: (a) Install the battery. (b) Check the connection between the battery power source and servo drive. (c) Check the encoder wiring. 4. Ensure the wiring is correct so that the battery power is supplied to the encoder and then re-establish the absolute origin coordinates. How to clear the alarm? Connect or reconnect the wiring so that the battery power is supplied to the encoder and then re-establish the absolute origin coordinates. Refer to Section 10.3.4 Establish the absolute origin coordinates for details. AL061 Encoder undervoltage Trigger condition and cause Condition: voltage level of the absolute encoder battery is lower than the rated value (3.1V). Cause:

voltage level of the battery is too low. Checking method and corrective action 1. Read the battery voltage with monitoring variable 26h to see if it is below 3.1V. 2. Measure the battery voltage to see if it is below 3.1V. If the voltage is too low, replace the battery when the servo drive’s main power is on. How to clear the alarm? The alarm is cleared automatically.