Delta Electronics — 12.2 Causes and corrective actions

Troubleshooting ASDA-B3 AL127 PDO object is write-protected when servo drive is on Trigger condition 12 and cause PDO object is write-protected (unchangeable) when servo drive is on. Checking method and corrective action Make sure no specified object is written when the servo drive receives or sends PDO in the Servo On state. How to clear the alarm? NMT: reset node, 0x6040 fault reset, or DI.ARST. 12-36 AL128 Error occurs when PDO object is read from EEPROM Trigger condition and cause An error occurs when the default value is loaded from ROM at start-up. All objects automatically return to the default value.

Checking method and corrective action Check if an error occurs because the specified object reads from EEPROM when the servo drive receives or sends PDO. How to clear the alarm? NMT: reset node, 0x6040 fault reset, or DI.ARST. AL129 Error occurs when PDO object is written to EEPROM Trigger condition and cause An error occurs when the current parameter value is saved to ROM. Checking method and corrective action Check if an error occurs because the specified object is written to EEPROM when the servo drive receives or sends PDO. How to clear the alarm? NMT: reset node, 0x6040 fault reset, or DI.ARST.

AL130 Accessing address of EEPROM is out of range Trigger condition and cause The quantity of the data in the ROM is greater than the allowable space specified by the firmware. It is probably because the firmware has been updated, but the data in the ROM was stored by the firmware of the previous version. Checking method and corrective action Check if the addressing in EEPROM exceeds the range for the specified object when the servo drive receives or sends PDO. How to clear the alarm? NMT: reset node, 0x6040 fault reset, or DI.ARST.