Delta Electronics — 12.2 Causes and corrective actions

ASDA-B3 Troubleshooting 12 12-39 AL207 Parameter group of PR#8 is out of range Trigger condition and cause Condition: parameter group of PR#8 is out of range. Cause: the group of PR#8 command source exceeds the range. Checking method and corrective action Write parameter using PR procedure: when the parameter group of command source exceeds the range, check the group setting of the written parameters. How to clear the alarm? DI.ARST AL209 Parameter number of PR#8 is out of range Trigger condition and cause Condition: parameter number of PR#8 is out of range. Cause: the number of PR#8 command source exceeds the range. Checking method and corrective action Write parameter using PR procedure:

when the parameter number of command source exceeds the range, check the number setting of the written parameters. How to clear the alarm? DI.ARST AL213 Parameter setting of PR#8 is in error Trigger condition and cause Condition: when you use PR#8 to write parameters, the parameter value is incorrect. Cause: an error occurs when you write parameters with PR#8 command. Checking method and corrective action Make sure the parameter value is within the correct range. How to clear the alarm? DI.ARST AL215 Write parameters: read-only Trigger condition and cause Condition: when you use the PR procedure to write parameters, the parameter is read-only. Cause:

an error occurs when you write parameters with PR#8 command. Checking method and corrective action The specified parameter is read-only. How to clear the alarm? DI.ARST