Delta Electronics — 12.2 Causes and corrective actions

Troubleshooting ASDA-B3 12 12-42 AL283 Software positive limit Trigger condition and cause Condition: the target position specified by the command exceeds the software positive limit. Cause: the software positive limit is triggered. Checking method and corrective action The software positive limit is determined by the Position command instead of the actual feedback position because the command is sent before the feedback is received. That is, the actual position may not have exceeded the limit when this limit protection is enabled. Set the appropriate deceleration time to achieve the desired effect. For more information, refer to the description of P5.003. How to clear the alarm?

The alarm is automatically cleared after the motor moves away from the limit. AL285 Software negative limit Trigger condition and cause Condition: the target position specified by the command exceeds the software negative limit. Cause: the software negative limit is triggered. Checking method and corrective action The software negative limit is determined by the Position command instead of the actual feedback position because the command is sent before the feedback is received. That is, the actual position may not have exceeded the limit when this limit protection is enabled. Set the appropriate deceleration time to achieve the desired effect.

For more information, refer to the description of P5.003. How to clear the alarm? The alarm is automatically cleared after the motor moves away from the limit. AL289 Position counter overflows Trigger condition and cause Position counter overflows. Checking method and corrective action 1. Set the gear ratio according to the actual application requirements and the total traveling distance of the absolute motor to avoid overflow of the feedback counter. 2. If P2.069.Z is set to 1 (function of preventing indexing coordinate from overflow), set P2.070 [Bit 2] to 1. How to clear the alarm? DI.ARST