ASDA-B3 Specifications A A-3 100 W 200 W 400 W 750 W 1 kW 1.5 kW 2 kW 3 kW ASDA-B3 01 02 04 07 10 15 20 30 Speed control mode Torque limit Parameter settings / Analog input Bandwidth Maximum 3.1 kHz ±0.01% at 0% to 100% load fluctuation Speed calibration ±0.01% at ±10% power fluctuation ratio*2 ±0.01% at 0˚C to 50˚C (32˚F to 122˚F) ambient temperature fluctuation Torque control mode Voltage -10 to +10 VDC range Analog Input 1 M command impedance input Time 25 µs constant Command source External analog command / Register Smoothing method Low-pass filter Speed limit Parameter settings / Analog input Monitor signal can be set by parameters (voltage output range:
±8V); resolution:10-bit Analog monitor output Digital input / output Servo on, Fault reset, Gain switch, Pulse clear, Zero speed clamping, Command input reverse control, Internal position command trigger, Torque limit, Speed limit, Internal position command selection, Motor stop, Speed command selection, Speed / position mode switching, Speed / torque mode switching, Torque / position mode switching, PT / PR command switching, Emergency stop, Positive / negative limit, Original point, Forward / reverse operation torque limit, Homing activated, Forward / reverse JOG input, Event trigger, E-Gear N selection, Pulse input prohibition Input A, B, Z line driver output Servo ready, Servo on, Zero speed detection, Target speed reached, Target position reached, Torque limiting, Servo alarm, Magnetic brake control, Homing is complete, Early warning for overload, Servo warning, Position command overflows, Software limit (negative direction), Software limit (positive direction), Internal position command is complete, Capture procedure is complete, Servo procedure is complete Output Overcurrent, Overvoltage, Undervoltage, Overheat, Regeneration error, Overload, Excessive speed deviation, Excessive position deviation, Encoder error, Adjustment error, Emergency stop, Forward / reverse limit error, Serial communication error, RST leak phase, Serial communication timeout, Short-circuit protection for terminals U, V, W and CN1, CN2, CN3 Protection function Communication interface RS-485 / USB / CANopen / DMCNET / EtherCAT Indoors (avoid direct sunlight), no corrosive vapor (avoid fumes, flammable gases, and dust) Installation site Altitude Below 2,000 m above sea level Atmospheric pressure 86 kPa - 106 kPa Environment 0˚C - 55˚C (32˚F - 131˚F) (If the operating temperature is above 45˚C (113˚F), forced cooling is required) Operating temperature Storage temperature -20˚C to 65˚C (-4˚F to 149˚F) Humidity Under 0 - 90% RH (non-condensing) Vibrating 9.80665 m/s2 (1 G) less than 20 Hz, 5.88 m/s2 (0.6 G) 20 to 50 Hz