CHAPTER 3 ~- TROUBLESHOOTING AND MAINTENANCE “ AREA 51 OPERATOR’S MANUAL Maintenance Procedures Introduction This section describes the maintenance procedures for all of the major assemblies and components of the game. The maintenance procedures should be performed every 3-4 months on a regular basis. WARNING Before performing any maintenance or repairs, please observe all of the following safety precautions: 1. Turn the game's power off. 2. Unplug the power cord from the electrical socket. 3. Secure loose clothing such as ties and long sleeves that could get caught within the game. 4. CAUTION Never lubricate the coin mechanism with oil or grease.

Troubleshooting Procedures This section is designed to help determine the source of a malfunction and provide detailed information on repairing the problem. Table 3-1 General Troubleshooting, is divided into two columns. The left-hand column is broken down into the general nature of problems. The right-hand column lists suggested solutions to solve the problem. Table 3-2 Area 51 PCB LED Indicators Troubleshooting, helps determine the cause of problems with the computer circuit boards or the hard disk drive by checking the status of the indicator LED’s. The left-hand column lists the various states.

The middle column explains the meaning of Remove all metal jewelry such as watches and necklaces that could conduct electricity from the game's power the state. The right-hand column suggests actions to cor- sources. Table 3-3 Computer System Troubleshooting, helps determine the cause of game operation problems. The lefthand column list symptoms. The middle column explains rect a problem. Cleaning Procedure for Coin the probable cause of the symptom. The right-hand col- Mechanisms umn suggests actions to correct a problem. Regular use of the coin mechanisms may result in a buildup of residue and dirt.

If this is the case, clean the coin mechanism by following the steps below (refer to Repair Procedures Figure 4-3 for detailed part information on the coin door). 1. Open the upper coin door. 2. Open the gate on the door that covers the magnet. Use the blade of a screwdriver to scrape away any metal filings that have collected on the magnet. 3. Clean the loose dust and dirt from the coin mechanism with a lint-free rag or a soft brush. 4. Clean the dirt and residue from the coin path with a toothbrush. Hot, soapy water may be used to help dissolve dirt and residue. 5. Blow out all the loose dirt and dry the coin mechanism with compressed air. 6.

Close the gate on the door that covers the magnet and close the upper coin door. Introduction This section describes the repair procedures for all of the major assemblies and components of the game. Before performing any repairs, use the tables in the Troubleshooting Procedures section and the screens in the Self Test software to help determine the source of the problem. The Maintenance Procedures section may also provide a good starting point for fixing many game problems before beginning what might be unnecessary repairs. Speaker Each game has a single speaker located in the middle of the control panel. The speaker provides the music and sounds for the game and self-tests.

Failure of the speaker may result in distorted or no sound. If this is the case,