MAN — 15.10.4 Standard Life Coolant Additive Maintenance Procedures

EuroV MBE 900 Operators Manual Laboratory Testing Laboratory testing is the best practice for determining ELC coolant quality and will provide vital information regarding the engine performance. A factory coolant analysis program is available through authorized Detroit™ service outlets. To verify coolant acceptability, submit a sample for coolant analysis according to Table "Extended Life Coolant". However, a laboratory meeting ISO 17025 requirements may be used in place of the Detroit™ Genuine Parts Program laboratory. OAT Detection Strips OAT Detection Strips that monitor the organic acid levels can be used to test the concentration of corrosion inhibitors in the anti-freeze coolant.

Detroit™ recommends consultation with your coolant manufacturer's technical representative for proper application. ELC Enhancers/Extenders ELC enhancers/extenders can be used to extend the life of the coolant. These products should be added to your anti-freeze coolant when corrosion inhibitors fall below manufacturer’s recommendations. Detroit™ recommends consultation with your coolant manufacturer’s technical representative for proper application. When coolant has reached the end of life, it is recommended to properly clean your cooling system of any scale, deposits or any other contaminants that may reduce the efficiency of the heat transfer.

The coolant must be drained completely including the block, radiator, and HVAC system. Next, flush the system with fresh, clean water. Replace drain fittings. Mix required amount of Penray 2010 cleaner in a 5-gallon pail of water and pour into radiator inlet. Fill system completely with clean water. Re-circulate cleaning solution by idling engine for 2 hours after top hose is hot. Temperature should be 88° to 95°C (190 to 203єF) to allow the thermostat to open. Drain, Flush, and Refill Procedure (See Appendix C for Product Part number) Drain cleaning solution from the system. The radiator, block and HVAC system must both be drained.

Flush with clean water (through the radiator inlet) for 3 to 5 minutes. Replace drain fittings. Mix required Penray 2011 in a 5-gallon pail and pour into radiator inlet (1 pound per 4 gallons cooling system capacity). Fill system completely with clean water. Re-circulate the Penray 2011 conditioning solution by idling engine for 15 minutes after the top hose is hot (thermostat opens if it wasn’t removed). Drain the Penray 2011 solution from the system. The radiator, block and HVAC system must both be drained. Flush with clean water for 3-5 minutes. Keep flushing as long as water looks “rusty” or “turbid.” Replace drain fittings.

Recharge cooling system with the appropriate ratio of clean water and the proper antifreeze for your application. 15.10.4 Standard Life Coolant Additive Maintenance Procedures The concentrations of SLC inhibitors will gradually deplete during normal engine operation. SCAs replenish the protection for cooling system components and must be added to the cooling system on an as needed basis. Below are test procedures that will assist in determining the inhibitor concentration. 15.10.4.1 Coolant Test Procedure 3-Way Test Strips Nitrite concentration is an indication of the overall coolant inhibitor concentration in SLC formulations.

These coolants must be tested for nitrite concentration at the regular intervals as listed in Table "Standard Life Coolant". Detroit™ Genuine Fluid Analysis 3-Way Test Strips (or equivalent) are recommended. Use these test strips to measure nitrite and glycol concentrations. Cavitation/corrosion protection is indicated on the strip by the level of nitrite concentration. Freeze/boil-over protection is determined by glycol concentration. Laboratory Testing As an alternative to the test strips, a factory coolant analysis program is available through authorized Detroit™ service outlets.

To verify coolant acceptability, submit a sample for coolant analysis according to Table "Standard Life Coolant". All information subject to change without notice. 55 DDC-SVC-MAN-0207 Copyright © 2019 DETROIT DIESEL CORPORATION