Test Boost pressure sensor Flash code: 5x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Boost pressure sensor Signal too high Signal too low Signal implausible with atmospheric pressure sensor (in control unit) Effect of fault: 60 to 70 % reduction in power Possible cause: Line break, short-circuit, boost pressure sensor faulty, control unit faulty Test precondition: EDC control unit connected Socket box connected “Ignition” switched on 33 Test Measurement Corrective measures Power supply Measure voltage at socket box across pin 33 (+) and pin 13 (–) Setpoint:
4.75–5.25 V – Check lines – Check plug connections – If no fault found, replace control unit (disconnect the control unit onl y wh en the current is switched off) Signal voltage Measure voltage at socket box across pin 36 (+) and pin 13 (–) Setpoints: Lower idle speed: 0.94–1.20 V Upper idle speed: 1.10–1.70 V If all the values are OK, the atmospheric pressure sensor in the control unit may be faulty – Replace control unit (only dis- connect control unit once the current is switched off)