MAN Nutzfahrzeuge Aktiengesellschaft — Control rod position sensor

Test Control rod position sensor Flash code: 6x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Control rod position tranducer Signal too high Signal too low Effect of fault: This fault results in the engine being shut down by setting the control rod travel to 0. The engine cannot be started if this fault is currently present (EDC indicator lamp permanently on). Possible cause: Line break, short-circuit, too little capacitance reserve (see page 26), control rod position sensor set incorrectly, injection pump faulty Test precondition:

EDC control unit disconnected Corrective measures 34 Test Measurement Corrective measures Instrument coil Measure resistance at socket box across pin 11 and pin 9 Setpoint: 18–25 Ω – Check lines – Check plug connections – If no fault found, repair injection pump Reference coil Measure resistance at socket box across pin 11 and pin 10 Setpoint: 18–25 Ω Measure resistance at socket box across pin 18 and pin 9 Setpoint: > 10 MΩ Measure resistance at socket box be- tween pin 18 and pin 10 Setpoint:

> 10 MΩ In addition to the possibility of an electrical fault, the fault described here may also be caused by incorrect setting of the control rod position sensor – Remove injection pump – Adjust control rod position sen- sor