MAN Nutzfahrzeuge Aktiengesellschaft — Atmospheric pressure sensor (in control unit)

Test Atmospheric pressure sensor (in control unit) Flash code: 2x long, 8x short Fault indication: Fault is indicated by the EDC indicator lamp coming on continuously Fault path: Atmospheric pressure sensor in control unit faulty Effect of fault: The power reduction at high altitudes for the protection of the exhaust turbo- charger is not activated Possible cause: Control unit faulty 46 Test Measurement Corrective measures Control unit If only this fault code is stored in the memory, testing is not possible, as the sensor is located in the control unit.

If, however, a faulty boost pressure sen- sor is also detected, this should be checked first in accordance with the boost pressure sensor test (page 33). – Replace control unit (only dis- connect the control unit once the current is switched off)