MAN Nutzfahrzeuge Aktiengesellschaft — Control rod position sensor - loose contact

Test Control rod position sensor – loose contact Flash code: 3x long, 10x short Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Control rod position tranducer Signal too high Signal too low Effect of fault: None Possible cause: Line break, short-circuit, too little capacitance reserve (see page 26), control rod position sensor set incorrectly, injection pump faulty Test precondition: EDC control unit disconnected Socket box connected 52 Test Measurement Corrective measures Instrument coil Measure resistance at socket box across pin 11 and pin 9 Setpoint:

18–25 Ω – Check lines – Check plug connections – If no fault found, repair injection pump Reference coil Measure resistance at socket box across pin 11 and pin 10 Setpoint: 18–25 Ω Measure resistance at socket box across pin 18 and pin 9 Setpoint: > 10 MΩ Measure resistance at socket box be- tween pin 18 and pin 10 Setpoint: > 10 MΩ In addition to the possibility of an electrical fault, the fault described here may also be caused by incorrect setting of the control rod position sensor – Remove injection pump – Adjust control rod position sen- sor