MAN Nutzfahrzeuge Aktiengesellschaft — PBM interface

Test PBM interface Flash code: No code Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: Control unit input pin 52 Faulty Interrupted Effect of fault: No PBM signal at pin 29 (steady voltage U-Batt) Possible cause: short to negative, line break Test precondition: EDC control unit connected Socket box connected “Ignition” switched off Note: Battery voltage must be applied at pin 52 against pin 18/19 with the “ignition” switched on. 53 Test Measurement Corrective measures Lines Measure resistance at socket box across pin 52 and pin 19 Setpoint: ∞ Ω – Check line – Replace control unit Measure resistance at socket box across pin 29 and pin 19 Setpoint: ∞ Ω