Test Electrohydraulic shut-off device EHAB Flash code: No code Fault indication: Fault is not indicated by the EDC indicator lamp Fault path: EHAB function Effect of fault: Engine is shut down Engine will not start (in this case it is assumed, that the fuel supply is OK) Function: The EHAB performs an important safety function in its capacity as an indepen- dent, higher-ranking (redundant) engine shut-off device The EHAB is activated in certain emergency situations when the engine can no longer be shut off by controlling fuel delivery to zero – e.g. when the control rod has jammed. The EHAB reduces the pressure in the suction chamber of the injection pump, thus interrupting filling.
Possible cause: Line break, short-circuit, EHAB defective, faulty activation from control unit (control unit defective) Test precondition: EDC control unit connected Socket box connected Note: When bleeding the fuel system using the presupply pump, power must be supplied to the EHAB, i.e. the fuel system cannot be bled without the “ignition” being switched on . See page 26 for function test. 54 Test Measurement Corrective measures Coil resistance Switch off “ignition” Disconnect control unit Measure resistance at socket box across pin 14 and pin 19 Setpoint:
30–70 Ω – Check line – Replace control unit – Replace EHAB Voltage supply Switch on “ignition” Measure voltage at socket box across pin 14 (+) and pin 19 (–) Setpoint: U-Batt – Check line – Replace control unit – Replace EHAB If no fault found: – Replace control unit (only disconnect control unit once the current is switched off)