Komatsu — Clean inside of cooling system

4.9 Service procedure Maintenance When required Use city water for the cooling water. If river water, well water or other such water supply must be used, contact your KOMATSU distributor. We recommend use of an antifreeze density gauge to control the mixing proportions. ! Prepare a container whose capacity is larger than the speci- fied coolant volume to catch drained coolant. ! Prepare a water inlet hose. 1. Stop the engine and tighten 2 valves (1) of the corrosion resistor. 1 GK038099 2.

Check that the cooling water temperature has gone down enough to make it possible to touch the radiator cap surface by hand, then turn radiator cap (2) slowly until it contacts the stopper to release the pressure. 2 3. Following this, push radiator cap (2), turn it until it contacts the stopper, then remove it. GK038100 4. Prepare a container to catch the antifreeze mixture, then open drain valve (3) on the left side of the fuel tank and drain the water. 5. After draining the water, close drain valve (3) and fill with city water. 6. When the radiator is full, start the engine, and run it at low idle.

3 Keep the engine running at low idle for 10 minutes until the coolant temperature reaches more than 90°C. GK038099 7. Stop the engine, open drain valve (3), drain the water, then tighten them again. 8. After draining the water, clean the cooling system with clean- ing agent. For the cleaning method, see the instructions for the clean- ing agent. WA380-6H – VEAM440100 4-37