4.9 Service procedure Every 100 hours service Maintenance 4.9.7 Every 100 hours service Maintenance for every 50 hours service should be carried out at the same time. Lubricate rear axle pivot pin (3 places) 1. Using a grease pump, pump in grease through the grease fittings marked by the arrows. 2. After greasing, wipe off any old grease that was pushed out. GK038107 Check oil level in hydraulic tank, add oil ! The parts and oil are at high temperature after the engine is stopped, and may cause burns. Wait for the temperature to go down before starting the work. ! When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it. 1.
Lower the bucket horizontally to the ground and stop the engine. Wait for 5 minutes, then check sight gauge (G). The oil level should be between the H and L marks. NOTE Do not add oil above the H line. This will damage the hydraulic circuit or cause the oil to spurt out. If oil has been added to above the H level, stop the engine and wait for the hydraulic oil to cool down, then drain the excess oil from drain plug. GK038108 G F 2. If the oil is below the L level, open the inspection cover above the step and add oil through oil filler port (F). 4-56 WA380-6H – VEAM440100 WARNING WARNING