Komatsu — Clean element in air conditioner fresh air filter

4.9 Service procedure Maintenance Every 100 hours service Clean element in air conditioner fresh air filter If compressed air is used, there is danger that dirt may fly and cause personal injury. Always wear safety glasses, dust mask, and other protective equipment. If the air conditioner has been used, the air filter should be cleaned. Stop the air conditioner before cleaning the element. When replacing the air filter element, set the machine facing directly to the front or articulate it to the right. 1. Insert the starting key into key slot (1), release the lock, loosen knob (2), and open cover (3). 2 3 1 GK038109 2. Remove element (4) and clean it. 3.

Direct dry compressed air (less than 0.69 MPa) to the ele- ment from inside along its folds, then direct it from outside along its folds and again from inside. If the dirt clogging the filter cannot be removed by blowing it with air, replace the filter with a new part. 4. After cleaning, return filter (4) to its original position and close the cover. Use the starting switch key to lock the cover. Do not forget to remove the starting switch key. REMARK If the filter becomes clogged, the air flow will be reduced, and there will be an abnormal noise from the air conditioner unit. WA380-6H – VEAM440100 4-57 WARNING WARNING 4 GK038110