John Deere 230LCR, 230LCRD — CHAPTER 5

TM 5-3805-280-10 Operating the Engine STARTING THE ARCTIC STARTER Move switch (A) to ON position. A continuous green on the LED light (B) indicates the system is operating properly. There is a normal delay of up to 90 seconds before actual ignition of the heater burner. If the LED light (B) flashes green something in the system sequence did not occur properly and default sensors have shut down the heater start-up. If this occurs, move switch (A) to OFF position for 15 seconds and then move switch to ON position. If the LED light (B) does not stay a continuous green after four consecutive tries, move switch (A) to OFF position and contact maintenance shop. NOTE:

Move switch (A) to ON position for two minutes with a continuous green LED light (B) once a month when it is not used. This will prevent the water pump and combustion engine from seizing. T125068 –UN–28OCT99 A—Heater Switch B—LED Light CED,OUOE020,14 –19–01MAR99–1/1 CHECK INSTRUMENTS AFTER STARTING IMPORTANT: Prevent possible damage to engine. If indicator lights do not go out after starting engine, IMMEDIATELY STOP THE ENGINE. Find and correct the problem. After the engine is started, the indicator lights should go out. If they do not, stop the engine immediately. Find and correct the problem. TX,25,DH3613 –19–27JUN95–1/1 5-8