John Deere 230LCR, 230LCRD — CHAPTER 7

TM 5-3805-280-10 Operating the Machine MODE SELECTION SWITCH Select operating modes by pressing the mode selection switch (A). In each mode, a microcomputer automatically selects the best combination of engine speed and pump flow rate that fits the working load. The dig mode (B) is automatically selected when the engine is started. Use the following as a guide: Dig Mode (B)—Designed for general digging and truck loading. Grading Mode (C)—Arm roll-in is slower for grading and finishing work. Precision Mode (D)—For work that requires precision front movement. Attachment Mode (E)—When using attachments other than the bucket.