TM 5-3805-280-10 Low Ambient Temperature Operation Two 24 volt DC heaters are provided at critical control system locations to prevent ice formation in the compressor capacity control system. One heater is attached to the surface of the pressure control valve. The other heater is attached to the bleed orifice connected to the compressor unloader valve. The heaters are turned on and off using the toggle switches located on either the local or remote compressor control panels. Allow the unit to warm up for at least (2) two minutes. Flip switch SW2 to the opposite position. Panel light PL2 will go out.

The engine should go to full speed and the discharge pressure rise to slightly over rated pressure. The compressor will unload (intake be throttled or closed) and the engine speed will drop to the idle speed. Compressor is now ready to furnish air when the service valve is opened. Below 40 degrees Fahrenheit Energize the heaters prior to starting the compressor drive engine. Allow the heaters to operate continuously during compressor operation. STOPPING Close air service valve (s). Allow the unit to run at “no load” for 3 to 5 minutes to reduce the engine temperatures. Below -25 degrees Fahrenheit Energize the heaters and wait 60 seconds prior to starting the excavator drive engine.

Allow the heaters to operate continuously during compressor operation. The unit may be stopped from either the local panel on the compressor or the optional start/stop panel if so equipped. Flip both toggle switches (SW1 and SW2) to the opposite position until both panel lights (PL1 and PL2) go out. Power is now off. Ether is an extremely volatile, highly flammable gas. Use sparingly! If too much is injected, the uncontrolled explosion may result in costly damage to the engine. Note: Once the engine stops, the automatic blowdown valve will begin to relieve all pressure from the receiver-separator system. Flip SW1 and SW2 until both panel lights are illuminated.

All DIAGNOSTICS lamps will light (glow) for two (2) seconds. Then all lamps should go off except for ALTERNATOR NOT CHARGING and LOW ENGINE OIL PRESSURE. Never allow the unit to sit stopped with pressure in the receiver-separator system. As a precaution, after the automatic blowdown period (2 minutes), open the manual blowdown valve. In cold weather, open manual blow down valve and, press the ETHER INJECT button once and release. Then, while cranking, press release button once every five (5) seconds. This injects a measured amount of ether to the engine. EQUIPMENT PROTECTION Note: Do NOT wire around or bypass a shutdown sensor or switch. Press the START button to crank the engine.

DO NOT OPERATE THE STARTER MOTOR FOR MORE THAN TEN (10) SECONDS WITHOUT ALLOWING AT LEAST ONE MINUTE COOLING TIME BETWEEN START ATTEMPTS. This unit is protected by sensors or switches at the following locations: (1) High engine COOLANT temperature in the engine. Release the START button when the engine starts and sustains running. If the engine does not start after a couple of attempts, refer to Trouble Shooting Section. (2) Low engine oil pressure, in the engine. (3) Low Fuel Level. High Discharge AIR Temperature - All Diagnostic lamps should be off. If not, stop the machine and investigate. If opened above, close manual blowdown valve. (4) At the airend outlet.