TM 5-3805-280-10 AUTOMATIC SHUTDOWN / DIAGNOSTICS Should any of these problem situations occur, the unit will automatically shutdown and stop. BEFORE restarting the unit or flipping the POWER switch to “Off”, check the DIAGNOSTICS area on the instrument panel. The upper four (4) lamps are electronically “latched” to only respond to the first or primary signal for a shutdown. In other words, if the automatic shutdown is the result of one of these four problems, only that particular problem lamp will be lit. And the lamp will remain lit as long as the batteries provide power. Refer to OPERATING CONTROLS AND INSTRUMENTS, for the various problem signal criteria ( ° F, psi, etc.).
The indicated problem area should be inspected for a physical cause (low fluid, broken fan belt, evidence of excessive heat, etc.) and corrections made. The shutdown will automatically reset when the problem condition is corrected. Other possible causes for an unexpected shutdown are listed on the Trouble Shooting Chart. 7-36