TM 5-3805-280-10 Operating the Machine USING QUICK-COUPLER TYPE ATTACHMENTS GENERAL OPERATING TIPS IMPORTANT: To avoid damaging machine cylinder(s), do not strike ground with attachment or operate with cylinders fully extended or retracted. Do not operate the attachment with the hydraulic cylinder rods fully extended or fully retracted. Do not strike the ground or other objects with the attachment. T120404 –UN–25MAR99 KEEPING HYDRAULIC SYSTEM CLEAN IMPORTANT: To prevent damage to hydraulic components, keep contamination from entering hydraulic system. Use wrench to loosen connectors when connecting and disconnecting hydraulic lines to attachment.
While attaching or detaching attachments, the hydraulic lines are open. Contamination can enter the hydraulic system at this time, causing machine damage. If attachments are changed frequently, there are more opportunities for contamination to enter the hydraulic system. To keep hydraulic oil contamination to a minimum: Clean connectors before disconnecting hydraulic lines. Install caps and plugs on hydraulic lines as soon as possible. Change hydraulic return filter at half the normal interval (250 hours). Sample hydraulic oil every 500 hours.
(See OILSCAN PLUS in Periodic Maintenance chapter.) Follow OILSCAN PLUS recommendations for oil change interval, but never change the oil less frequently than recommended for the machine. OILSCAN PLUS is a trademark of Deere & Company. CED,OUOE020,17 –19–09DEC99–1/1 7-37