TM 5-3805-280-10 Maintenance—Every 1000 Hours 4. Remove wing nut and secondary element (B). 5. Install elements, making sure the secondary element is centered in canister. 6. Install cover. T6119AG –UN–01NOV88 TX,85,FF2318 –19–01NOV91–2/2 INSPECT FAN BELT 1. Check belt regularly for wear, especially for cracks at the bottom of grooves and for frayed edges. 2. If necessary, replace belt. 3. Install a 15 mm wrench to the TOP pulley (A) of belt tension adjuster. Turn wrench counterclockwise to pull tension adjuster pulley away from belt, releasing belt tension. 4. Hold tension adjuster away from belt while removing old belt and installing new belt. 5.
Slowly release wrench tension to allow tension adjuster to move clockwise against new belt. Tension is automatically adjusted. 6. Remove wrench. T108219 –UN–25MAR97 TX,85,DH5557 –19–17DEC96–1/1 REPLACE AIR CLEANER DUST VALVE NOTE: A missing, damaged, or hardened dust valve will cause the air filter elements to be ineffective. Replace dust valve (A). T101488 –UN–15JUL96 TX,85,DH5094 –19–08JUL96–1/1 16-8