TM 5-3805-280-10 Maintenance—Every 2000 Hours CAUTION: High pressure release of oil from pressurized system can cause serious burns or penetrating injury. The hydraulic tank is pressurized. Do not remove vent plug (A). Release pressure by loosening vent plug. T7869AT –UN–12NOV92 9. Loosen vent plug (A) to relieve air pressure. TX,OUOE042,29 –19–08MAR99–2/7 10. Insert 4 mm (0.15 in.) hex wrench (D) into hole (E) and turn counterclockwise. 11. Slowly turn cap (A) counterclockwise. Remove cap. Hydraulic Tank Oil—Specification Capacity 148 L (39 gal) ...............................................................................
T6457EI –UN–18OCT88 A—Cap B—Aligning Marks C—Case Assembly D—Hex Wrench E—Hole Continued on next page TX,OUOE042,29 –19–08MAR99–3/7 17-6