TM 5-3805-280-10 MAINTENANCE – AIR COMPRESSOR GENERAL In addition to periodic inspections, many of the components in these units require periodic servicing to provide maximum output and performance. Servicing may consist of pre- operation and post-operation procedures to be performed by the operating or maintenance personnel. The primary function of preventive maintenance is to prevent failure, and consequently, the need for repair. Preventive maintenance is the easiest and the least expensive type of maintenance. Maintaining your unit and keeping it clean at all times will facilitate servicing.
This machine was factory filled with Ingersoll-Rand Pro TecR Compressor Fluid (Ingersoll-Rand XHP505 for XHP900 models). Compressor Oil Correct engine speed is critical to the operation of this machine. Check the idle and full load rpm every three months and adjust in accordance with the speed and pressure adjustment instructions in this manual and included on a decal on the machine. Correct speeds are on the general data decal. SCHEDULED MAINTENANCE The maintenance schedule is based on normal operation of the unit. This page can be reproduced and used as a checklist by the service personnel.
In the event unusual environmental operating conditions exist, the schedule should be adjusted accordingly. COMPRESSOR OIL LEVEL The oil level is most consistent when the unit is RUNNING AT FULL LOAD and should be checked at this time.The optimum operating level is midway of the sight tube on the side of the receiver tank. See the decal beside the sight tube. If the oil level is not in the “OK” range, make appropriate corrections (Add or Drain). A totally filled sight tube in which the level is not visible indicates an over-full condition and requires that oil be drained. 18-1