TM 5-3805-280-10 The compressor oil must be replaced every 500 hours of operation or six (6) months, whichever comes first for models HP600 - P1600. Refer to the fluids and lubricants chart for ambient temperature ranges and specifications, in the lubrication section of this manual. The compressor oil must be replaced every 500 hours of operation or six (6) months, whichever comes first for models P100-P600. The compressor oil must be replaced every 1000 hours of operation or six (6) months, whichever comes first for models HP600-P1600. Refer to the fluids and lubricants chart for ambient temperature ranges and specifications in the lubrication section of this manual. AIR CLEANER 3.
Wipe inside of air cleaner housing with a clean, damp cloth to remove any dirt accumulation, especially in the area where the element seals against the housing. The Model XP330SCU is equipped with air cleaner service indicators mounted on the main instrument/control panel. 4. Inspect element by placing a bright light inside and rotating slowly. If any holes or tears are found in the paper, discard this element. If no ruptures are found, the element can be cleaned by one of the following procedures. Inspect daily the air cleaner service indicator. Never guess about restriction in the air cleaner. Always know what condition your air cleaner is in with the assistance of the service indicator.
If it is not working properly, or is missing, replace it. Maximum compressor and engine protection against the ravages of dust is possible only if the air cleaner is serviced at regular intervals or whenever the service indicator shows red. 5. If a new air filter element is to be used check it closely for shipping damage. To reset the signal indicator in the special wing nut, apply suction to the red window. Visually inspect the position of the flag in the air cleaner restriction indicator. Normally, the flag in a service indicator shows green, indicating the filter element is still serviceable.
If the flag shows red when the unit is operating at full speed or stopped, it is an indication that proper servicing of the filter element is necessary. 6. Install cleaned or new elements in the reverse order to the above. Tighten wing nuts firmly and replace cotter pin. 7. Inspect to ensure that the end cap seals tightly 360 degrees around the air cleaner body. Also weekly squeeze the rubber valve (precleaner dirt dump) on each air cleaner housing to ensure that they are not clogged. NOTICE: Holes or cracks downstream of the air cleaner housing will cause the restriction indicators to be ineffective.
The air filters restricted sensor will automatically reset after the main power switch is flipped to “OFF.” To service the air cleaners on all units proceed as follows: 1. Loosen outer wing nut and remove with outer element. Inspect red window on special inner wing nut to find small dot. If dot is not visible, remove cotter pin and special wing nut and inner (safety) element. 2. Inspect air cleaner housing for any condition that might cause a leak and correct as necessary. 18-2