TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-3 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: WARNING: Always remember the CAUTIONS, WARNINGS, and NOTES before operating this machine and prior to PMCS. PREPARE MACHINE FOR MAINTENANCE Before performing PMCS and before leaving the operator’s seat, park the machine as described below unless another position is specified in the procedure. (1) Park machine on a level surface. (2) Lower bucket to the ground. (3) Turn auto-idle switch off. CAUTION:
Turbocharger may be damaged if engine is not properly shut down. (4) Run engine with engine rpm dial at 1/3 position without load for 2 minutes. (5) Move engine rpm dial to slow idle position. (6) Turn key switch to OFF. Remove key from switch. (7) Pull pilot control shut-off lever to locked position. Perform all weekly and before operations PMCS if: (1) You are the assigned operator and have not operated the machine since the last weekly. (2) You are operating the machine for the first time. WALK-AROUND CHECKS/INSPECTION Inspect machine daily before starting and after operation. NOTE: If leakage is detected, further investigation is needed to determine the location and cause of the leak.