TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-13 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 31 Before During (3) Make sure dipstick (A) is fully seated. (4) Remove dipstick and check oil level. (5) Add oil (filler cap [B]) if level is below ADD or cross-hatched area mark on the dipstick (see Fuels and Lubricants, Chapter 9). NOTE: BEFORE THE ENGINE IS STARTED: The engine is full when oil level is in the cross-hatched area. AFTER THE ENGINE HAS BEEN RUN:
Allow the oil to drain into the oil pan for 10 minutes after engine stops before checking the oil level. The oil level must be above the ADD mark. If necessary, remove oil filler cap (B) and add oil. (6) Inspect engine compartment for loose or damaged components. NOTE: Ensure that engine access door is closed securely after inspection is complete. Check Instruments (1) Turn key switch to ON position. All instrument lights should stay on for approximately 3 seconds. (2) Check and replace any bulb that fails to light. (3) Check that gauge indicates fuel level and the coolant gauge does NOT go to the red zone.
Oil level is below ADD level on the dipstick Any damage that would prevent operation Coolant gauge in red zon