TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-17 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 34 35 Before During Before (2) Insert 4 mm (0.15 in.) Allen wrench (D) into hole (E) and turn counterclockwise. (3) Slowly turn cap (A) counterclockwise. Remove cap. Add oil (see Fuels and Lubricants, Chapter 9). (4) Install cap to case assembly (C) by aligning marks (B) and turning clockwise to lock position. (5) Tighten vent plug. NOTE: Ensure that access door is closed securely after inspection is complete.
Perform Operational Checks (See Operational Checkout, Chapter 21.) Check Decontamination Kit Holder and Holder Strap (1) Check decontamination kit holder strap for fraying, cutting, or wear. Replace if necessary. (2) Ensure that decontamination kit holder bolts are tight. NOTE: The following checks and services are to be performed weekly or sooner as required by adverse environmental conditions.