TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-18 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 36 37 38 39 40 41 42 After Weekly Weekly Weekly Weekly Weekly Weekly Clean Rock Drill Dust Collector Filters (230LCRD) (1) Every day after drilling operations are completed and before stopping the machine, clean filters by allowing one cleaning cycle without drilling. Inspect Material Clamp Pin Joint Movement (230LCR) (1) Operate material clamp and check for unusual slop. Make sure pin joints are snug.
Inspect Quick-Disconnect Hitch Attachment Points (1) Ensure that attachment is secure in front hooks and rear saddle. (2) Inspect quick-disconnect hitch and wedge for excessive wear, damage, or failure. Inspect Quick-Disconnect Hitch Lifting Hook (1) Visually inspect lifting hook for wear or damage. NOTE: Items 40 through 42 are applicable to Model 230LCRD only. Wash the Rock Drill Inspect All Hoses of Rock Drill (1) Inspect hoses for cracking, wear, or damage. If hoses require replacement, notify your supervisor.
Check the Rock Drill Cap Bolts and the Mounting Bolts of the Hydraulic Drifter for Tightness Clamp action is sloppy Any damage that would prevent operation Any damage that would prevent operation Hoses are damaged and leaking Bolts are loose or missing