TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-22 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 52 *As Required (2) Open drain valve (A) and press pump (B) to extract water. Collect waste in a container and dispose of properly. (3) Close drain valve (A). NOTE: Ensure that access door is closed securely after inspection is complete. Clean Air Cleaner Unloader Valve NOTE: A missing, damaged, or hardened dust unloader valve will make the dust cup precleaner ineffective, causing very short air filter life.
Valve should suck closed above 1/3 engine speed. (1) Squeeze dust valve (A) to remove dust from the air cleaner. (2) When operating in high dust/sand conditions, squeeze dust valve every couple of hours of operation to release dust/sand.