John Deere 230LCR, 230LCRD — APPENDIX A

TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-25 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 56 57 58 59 Monthly Monthly Monthly Monthly Run Arctic Starter Heater (1) Switch heater on (for 2 minutes with a “continuous green” LED light) once a month during periods when heater is not used. This will prevent the water pump and combustion engine from seizing. Check Arctic Starter Glow Pin (1) Check glow plug cable and connection. Make sure that connection is not corroded or dirty.

Inspect Fire Extinguisher (1) Check gauge on fire extinguisher. Make sure the dial is within the green area on the gauge. (a) Fire extinguisher located in cab (230LCR). (b) Fire extinguisher located in battery compartment (230LCRD). (2) Check tightness of fire extinguisher bracket bolts. (3) Check the fire extinguisher hose for cracks, wear, or damage. Replace if necessary. (4) Check that tamper seal is intact. Inspect Primary Air Cleaner Element (1) Open front service door. (2) Loosen wing nut to remove cover. (3) Remove wing nut and primary element (A). Clean the primary element. NOTE: Ensure that front service door is closed securely after inspection is complete.

Pressure is not within specification Primary element is damaged or dirty