TM 5-3805-280-10 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 230LCR/230LCRD A-24 ITEM NO. INTERVAL ITEM TO BE INSPECTED PROCEDURE: DO THE PMCS AND HAVE ITEM REPAIRED, FILLED, OR ADJUSTED AS NEEDED EQUIPMENT IS NOT READY/AVAILABLE IF: 55 Monthly (2) Loosen plug (F) for several seconds to drain water and sediment into a container. Do not remove plug completely. Dispose of waste properly. (3) Tighten sump plug and vent. Check Pump Drive Gearbox Oil Level To check oil: (1) Remove dipstick (A). (2) Wipe dipstick clean and insert completely into tube. (3) Remove dipstick. Oil must be approximately halfway below the “H” (level) mark. To add oil:
(1) Remove filler cap (B). (2) Add oil (see Fuels and Lubricants, Chapter 9). (3) Install filler cap. Oil level is below the AD SAFE mark on the dipsti