Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION WORK EQUIPMENT • SWING PPC VALVE Operation 1. At neutral a. Ports A and B of the control valve and ports P1 and P2 of the PPC valve are connected the drain chamber D through fine control hole f in spool (1). 2. During fine control (neutral ЖЖ fine control) a. When piston (4) starts the be pushed by disc (5), retainer (9) is pushed; spool (1) is also pushed by metering spring (2), and moves down. b. When this happens, fine control hole f is shut off from drain chamber D , and at al- most the same time, it is connected the pump pressure chamber PP , so pilot pres- sure oil from the main pump passes through fine control hole f and goes from port P1 the port A . c.

When the pressure at port P1 becomes higher, spool (1) is pushed back and fine control hole f is shut off from pump pres- sure chamber PP . At almost the same time, it is connected the drain chamber D the re- lease the pressure at port P1 .When this happens, spool (1) moves up and down so that the force of metering spring (2) is bal- anced with the pressure at port P1 . The re- lationship in the position of spool (1) and body (10) (fine control hole f is at a point midway between drain hole D and pump pressure chamber PP ) does not change until retainer (9) contacts spool (1). d.

Therefore, metering spring (2) is com- pressed proportionally to the amount of movement of the control lever, so the pres- sure at port P1 also rises in proportion to the travel of the control lever. In this way, the control valve spool moves to a position where the pressure in chamber A (the same as the pressure at port P1 ) and the force of the control valve spool return spring are balanced. 10-109