STRUCTURE AND FUNCTION EPC SOLENOID VALVE 1. Connector 2. Variable core 3. Coil 4. Cage 5. Spool 6. Block 7. Spring Operation 1. When solenoid is deactivated a. The signal current does not flow from the controller, so coil (3) is deactivated. For this reason, spool (5) is pushed to the right in the direction of the arrow by spring (6). b. As a result, the circuit between ports P and A closes and the pressurized oil from the main pump does not flow to the actuator. At the same time, the pressurized oil from the actuator flows from port A to port T , and is then drained to the tank. 2. When solenoid is excited a.

When the signal current flows from the controller to coil (3), coil (3) is excited. For this reason, spool (5) is pushed to the left in the direction of the arrow. b. As a result, the pressurized oil from the main pump flows from port P through the inside of spool (5) to port A , and then flows to the actuator. At the same time, port T is closed, and this stops the oil from flowing to the tank. 10-122