Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION OVERLOAD WARNING DEVICE 2) OPERATION 1. Boom cylinder safety valve 2. Boom cylinder 3. Tee-piece 4. Pressure sensor 5. Wiring harness The overload caution system is operated by pres- sure alone (it does not take into account the position of the boom-. The pressure sensor (4) located on the hose bal- ance line between each hose burst safety valve is activated when the oil pressureexceeds 190 kg/cm 2 during lifting operation. NOTE : the overload caution system can only be ac- tivated when the L/O mode (lifting operation) is acti- vated on the monitor panel, with active mode switched off. 10-124