Komatsu — eebm001902 a3.pdf

STRUCTURE AND FUNCTION ENGINE CONTROL Operating of system 1. Starting engine a. When the starting switch is turned to the START position, the starting flows to the starting motor, and the starting motor turns to start the engine. Power also flows to the fuel shut-off solenoid, exciting the solenoid and allowing fuel to flow into the engine. b. When this happens, the engine throttle • pump controller checks the signal from the fuel control dial and sets the engine speed to the speed set by the fuel control dial. 2. Engine speed control a. The fuel control dial sends a signal to the engine throttle • pump controller according to the position of the dial.

The engine throt- tle • pump controller calculates the angle of the governor motor according to this sig- nal, and sends a signal to drive the gover- nor motor so it is at that angle. b. When this happens, the operating angle of the governor motor is detected by the potentiometer, and the feedback is sent to the engine throttle • pump controller, so that it can observe the operation of the governor motor. 3. Stopping engine a. When the starting switch is turned to the OFF position, the engine throttle • pump controller drives the governor motor to the low idle position.

The fuel shut-off solenoid is de-energized when starting switch signal is turned OFF, so the supply of fuel to the engine is shut off and the engine stops. b. When this happens, to maintain the electric power in the system until the engine stops completely, the engine throttle • pump con- troller itself drives the battery relay. 10-133