TESTING AND ADJUSTING PC VALVE OUTPUT PRESSURE TESTING AND ADJUSTING PC VALVE OUTPUT PRESSURE (SERVO PISTON INPUT PRES- SURE) 1. Measuring # Oil temperature when measuring: 45 - 55°C Measure the oil pressure when the circuit is relieved in the pressure rise mode. a. Install oil pressure gauge C1 to quick disconnects (1), (2), (3), and (4). # Install a 39.2 MPa (400 kg/cm 2 ) gauge to the servo valve end, and a 58.8 MPa (600 kg/cm 2 ) gauge to the pump outlet port end. b. Turn the swing lock switch ON. c. Set the working mode to H/O mode. d. Run engine at full throttle, turn the knob switch ON, and measure the oil pressure when the arm (IN) circuit is relieved.
# Check that the servo piston input pressure is 1/2 of the pump discharge pressure. Note: If there is any abnormality in the LS valve or servo piston, the servo piston input pressure will be 0 or almost the same as the pump discharge pressure. 2. Adjusting # If the load becomes larger, the engine speed will drop. Or if the engine speed remains normal, the work equipment speed will drop. In such cases, if the pump discharge pressure and LS differential pressure are normal, adjust the PC valve as follows. a. Loosen locknut (4), and if the equipment speed is slow, turn screw (5) to the right; if the engine speed drops, turn the screw to the left.
# If the screw is turned to the right, the pump absorption torque will be increased, and if it is turned to the left, the pump absorption torque will be reduced. # The adjustment range for the screw is a maximum of 1 turn to the left and 180° to the right. # The amount of adjustment for one turn of the screw: 1.5 mm of servo piston stroke movement. b. After completing the adjustment, tighten the locknuts. BP00800 a - b Rear and front pump discharge pressure rest points c Pump bleed point d Servo piston input pressure test point of rear pump Locknut (3): 34.3 ± 4.9 Nm (3.5 ± 0.5 kgm) Locknut (4): 100.5 ± 12.3 Nm (10.25 ± 1.25 kgm) 20-37