TESTING AND ADJUSTING TESTING AND ADJUSTING HYDRAULIC PRESSUREIN WORK EQUIPMENT, SWING AND TRAVEL CIRCUIT 2. Adjusting (1): For front pump (2): For rear pump adjusting high pressure setting. Loosen locknut (3), then turn holder (4) to adjust. # Turn the holder to adjust as follows: To INCREASE pressure, turn CLOCKWISE. To DECREASE pressure, turn COUNTERCLOCK- WISE. # Amount of adjustment for one turn of holder: approxi- mately 12.5 MPa (128 kg/cm 2 ). Locknut: 53.5 ± 4.9 Nm (5.5 ± 0.5 kgm) # When the high pressure setting is adjusted, the low pressure setting will also change, so adjust the low pressure setting also. a. Adjusting low pressure setting.
Loosen locknut (5), then turn holder (6) to adjust. Turn the holder to adjust as follows: To INCREASE pressure, turn CLOCKWISE. To DECREASE pressure, turn COUNTERCLOCKWISE. # Amount of adjustment for one turn of holder: Approximately 12.5 MPa (128 kg/cm 2 ). Locknut: 53.5 ± 4.9 Nm (5.5 ± 0.5 kgm) # Normally, the pressure applied to port PX1 is 0 MPa (0 kg/cm 2 ); at the high pressure setting, it is 2.9 MPa (30 kg/cm 2 ). b. Swing motor safety valve. Loosen locknut (1), then turn adjustment screw (2) to adjust. # Turn the adjustment screw to adjust as follows. To INCREASE pressure, turn CLOCKWISE. To DECREASE pressure, turn COUNTERCLOCKWISE. 20-36