Komatsu — eebm001902 a3.pdf

TESTING AND ADJUSTING LS VALVE OUTPUT PRESSURE 2. Measuring LS differential pressure a. Measuring with a differential pressure gauge. i. Install one line of differential pressure gauge C4 to the main pressure port of the front (or rear) pump. ii. Install the second line of pressure gauge to the quick disconnects on the LS lines at the main control valve ( e and f ). (The LS lines are color coded at each end. Make sure to use the same LS line on both the pump end and the main valve end.) iii. Set the conditions in Table 2 and measure the LS differential pressure. Table 2 BP00800 a - b Rear and front pump discharge pressure test points e Rear LS pressure test point.

d Front LS pressure test point. u u 20-39 Working mode Fuel control dial Operation LS differential pressure (MPa (kg/cm2) H/O mode MAX Levers at neutral 2.94 ± 0.98 (30 ± 10) H/O mode MAX Travel speed: Hi Travel circuit under no load (lever half operated) 2.16 ± 0.1 (22 ± 1)