Komatsu — eebm001902 a3.pdf

TESTING AND ADJUSTING LS VALVE OUTPUT PRESSURE 3. Adjusting LS valve When the differential pressure is measured under the conditions above, and the results show that the differ- ential pressure is not within the standard value, adjust as follows. a. Loosen locknut (4) and turn screw (5) to adjust the differential pressure. Turn the screw to adjust the differential pressure as follows: To INCREASE pressure, turn CLOCKWISE To DECREASE pressure, turn COUNTERCLOCKWISE. # Amount of adjustment (LS differential pressure) for one turn of screw: 1.3 MPa (13.3 kg/cm 2 ). b. After adjusting, tighten locknut (4). Locknut: 56.4 ± 7.4 Nm (5.75 ± 0.75 kgm). Note:

Always measure the differential pressure while adjusting. 20-40