TESTING AND ADJUSTING ADJUSTMENT OF FLOW CONTROL SYSTEM ADJUSTMENT OF FLOW CON- TROL SYSTEM Purpose The flow control system limits the maximum flow of oil through the first attachment circuit dependent on the switch setting selected on the thumbwheel switch in the operator’s cab. It is possible to adjust the factory settings for oil flow rate by using the adjustment screw on the flow control unit itself. Special Equipment Required 1. Oil pressure gauge. To be of suitable range for accu- rate measurement of PPC pressure (0 kg/cm 2 to 30 kg/ cm 2 ). 2. Test Gauge Adaptor. To allow fitment of the above gauge to the excavator hydraulic system. Adaptor to suit KES # 02 type elbow and hose.
Method 1. Fit the pressure gauge at a suitable point in the pilot line between the output of the EPC valve and the con- trol valve. A suggested position is the port P -2 on the main valve. 2. Start the machine and run it at high idle in HO mode. 3. Select the desired switch setting on the cab switch (see section 2.3) then fully depress and hold down the RH attachment pedal. Take note of the pressure read- ing and refer to fig (i) to obtain a system flow rate for this pilot pressure. 4. If the measured value is acceptable then there is no need to alter the controller output. Switch the machine off and remove the test equipment. 5.
If the measured value requires adjustment, then re- move the rear panel behind the operator’s seat to gain access to the controller (refer to section 2.3 for loca- tion of the controller). The adjustment screw is upper- most on the controller. To adjust the controller output proceed as shown below: Slacken off the lock-nut. Turn the adjust screw clockwise to increase PPC pressure or anticlockwise to reduce PPC pres- sure. ADJUST SCREW 20-47